='''Software Description''' =  
='''Software Description''' =  


  This software was developed to download aircraft position during general aviation championships organized by the [https://www.ffa-aero.fr/ Fédération Française Aéronautique] ou la [https://www.fai.org/sport/general-aviation Fédération Aéronautique Internationale].  
  This software was developed to download aircraft position during General Aviation Championships organized by the [https://www.ffa-aero.fr/ Fédération Française Aéronautique] ou la [https://www.fai.org/sport/general-aviation Fédération Aéronautique Internationale].  
  FFA SkyTracq V6 is a device management software using the [https://www.skytraq.com.tw/products/products.html SkyTraq Venus 6 GPS] chipset.
  FFA SkyTracq V6 is a device management software using the [https://www.skytraq.com.tw/products/products.html SkyTraq Venus 6 GPS] chipset.
The most commonly logger is [https://www.conrad.fr/fr/p/enregistreur-gps-renkforce-gt-730fl-s-noir-373686.html Renkforce GT730FL-S]
The most commonly logger is [https://www.conrad.fr/fr/p/enregistreur-gps-renkforce-gt-730fl-s-noir-373686.html Renkforce GT730FL-S]
Ligne 34 : Ligne 34 :
===Gap between track===
===Gap between track===
Seconds between two points. If the duration reaches this value, a new item will be added to the grid
Seconds between two points. If the duration reaches this value, a new item will be added to the grid
If the value is set to 0 then all data will be in a single file


===Table threshold===
===Table threshold===
Ligne 44 : Ligne 46 :
*.gpx.
*.gpx.


===Com port automatic detection===
===COM port automatic detection===
On Windows 10 and above, check this box to enable automatic detection of the com port when the device is plugged into a USB connector
On Windows 10 and above, check this box to enable automatic detection of the COM port when the device is plugged into a USB connector


===Button GPS time -> UTC time===  
===Button GPS time -> UTC time===  
Ligne 73 : Ligne 75 :
To download a logger, plug to a USB connector
To download a logger, plug to a USB connector


If automatic detection of comm port is activated, the data are read and all track detected are displayed in the left windows.
If automatic detection of COM port is activated, the data are read and all track detected are displayed in the left windows.
*Each line provide start and finish timetrack (separation is done according '''Gap between track''' parameter)   
*Each line provide start and finish time track (separation is done according '''Gap between track''' parameter)   
*Track with duration less than '''Table threshold''' parameter is not displayed if checkbox '''Short list''' is ckecked
*Tracks with duration less than '''Table threshold''' parameter are not displayed if checkbox '''Short list''' is ckecked
[[Fichier:Short list.jpg|vignette]]
[[Fichier:Short list.jpg|vignette]]
*The last track is displayed in the right windows
*The last track is check and displayed in the right windows
 
To download click '''Download''' button


If the '''Filename of start list''' parameter is ckecked a windows is open.
To download
Double click on the competitor name to save the data formated according the extension name selected
*Click '''Download''' button
*If the '''Filename of start list''' parameter is ckecked a windows is open.
*Double click on the competitor name prefile the filename
*Save the data formated according to extension name selected


='''Clear the memory'''=
='''Clear the memory'''=
Ligne 106 : Ligne 109 :
*Select in the menu '''View ->  Show hidden devices'''
*Select in the menu '''View ->  Show hidden devices'''
[[Fichier:Show_hidden_devices.png|250 px]]
[[Fichier:Show_hidden_devices.png|250 px]]
*Expand '''Ports(COM & LPT)''' to list all COM ports hidden, com port have a grayed out icon next to them.
*Expand '''Ports(COM & LPT)''' to list all COM ports hidden, COM port have a grayed out icon next to them.
*Right click on the last port and select Uninstall. In the Confirm Device Removal dialog box, click OK.
*Right click on the last port and select Uninstall. In the Confirm Device Removal dialog box, click OK.
*Repeat for all unused ports
*Repeat for all unused ports

Dernière version du 21 août 2025 à 18:44

Software Description

This software was developed to download aircraft position during General Aviation Championships organized by the Fédération Française Aéronautique ou la Fédération Aéronautique Internationale. 
FFA SkyTracq V6 is a device management software using the SkyTraq Venus 6 GPS chipset.

The most commonly logger is Renkforce GT730FL-S

GT730FL-S
GT730FL-S

Install the software

Download the software from FFA website

Execute the file FFA_SkyTraq_V6 0.1.8_Setup.exe and select the language

Check the box to accept the licence agreement

Click button Install

Connexion device

Menu Tools > Set parameters

Main windows

Windows Set parameters

Set parameters

Directory

Directory where the data while be dowloaded.

Filename of start list

Check this box if you want to open a text file with the competitors name. This is usefull to synchronizing the data file with other software.

When the box is checked, a field appears to select the file.

  • We recommend that you provide a text file with the list of competitors sorted by start number : StartNumber_CompetitorName.

Gap between track

Seconds between two points. If the duration reaches this value, a new item will be added to the grid

If the value is set to 0 then all data will be in a single file

Table threshold

Seconds between the first and last point of track. If the duration is less than this value the lines will be hidden (checkbox Short list ckecked).

Default format

Select the output file format :

  • .gac,
  • .kml,
  • .gpx.

COM port automatic detection

On Windows 10 and above, check this box to enable automatic detection of the COM port when the device is plugged into a USB connector

Button GPS time -> UTC time

 Be careful before using this correction

The Skytraq Venus 6 chipset provides GPS time, correction with UTC time must be done by software. The deviation between GPS Time and UTC time is not a constant. Every six month leaps seconds can be introduced. See official website Observatoire of Paris.

The last additional second has been introduced on 1 January 2017, at 0hUTC. As of this date the delta betwen GPS time and UTC time was 18 seconds

See also official times

Next change will be announced to Bulletin C

Click the open window button to change the value

In GAC file the value of delta betwen GPS time and UTC time is written in the heading of the file under item HFGPSRECEIVER

Synoptic with all parameters

Set parameters

When all parameters are set click on Button save


Download the data

To download a logger, plug to a USB connector

If automatic detection of COM port is activated, the data are read and all track detected are displayed in the left windows.

  • Each line provide start and finish time track (separation is done according Gap between track parameter)
  • Tracks with duration less than Table threshold parameter are not displayed if checkbox Short list is ckecked
  • The last track is check and displayed in the right windows

To download

  • Click Download button
  • If the Filename of start list parameter is ckecked a windows is open.
  • Double click on the competitor name prefile the filename
  • Save the data formated according to extension name selected

Clear the memory

  • We do not recommend keeping a large amount of data in the logger's memory
  • Clear the memory frequently, after plugging in the logger, click Clear memory button

Logger configuration

This function is only enable if a logger is connected.

Menu Tools > Logger configuration

  • Select log time and set it to the minimum value of 1 second
  • Set Speed mini to 0
  • Check Data log enable
  • Click button Send to GPS

Cleaning COM ports unused

Whenever a new USB serial device is plugged into a PC, Windows will assign the device a new, unique COM Port number

To avoid reaching the maximum allowed by your system, unused COM ports should be cleaned up periodically

  • Plug a logger to the USB connector to activate COM ports
  • Open Windows Device Manager
  • Select the line Ports (COM & LPT)
  • Select in the menu View -> Show hidden devices

  • Expand Ports(COM & LPT) to list all COM ports hidden, COM port have a grayed out icon next to them.
  • Right click on the last port and select Uninstall. In the Confirm Device Removal dialog box, click OK.
  • Repeat for all unused ports

For advanced users only a quicker action can be performed using Regedit

  • Click start → Run → type regedit and click OK button
  • Export your regedit file to avoid mishandling
  • Navigate to HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\COM Name Arbiter
  • On the right panel, you can see the key ComDB.
  • Right-click it and click modify
  • In value Data section select all and delete reset to zero (0)(If you set the value to 0 all COM ports are free).
  • Close the registry editor and then restart your computer.